Overview
|
HP OpenView Storage Management Appliance III and HP OpenView Storage Management Appliance software v2.1
|
||||||||||||
| What's New |
|
| At A Glance |
|
| |
| Product Description/ Overview |
The HP OpenView Storage Management Appliance is a combined hardware and software solution that provides a centralized point for configuration, management and monitoring of storage elements, including switches and storage devices, while simplifying management tasks and reducing cost. It offers a comprehensive and cost-effective configuration, monitoring and storage management solution for the multiple platform SAN. Designed to connect directly to a SAN fabric, the Storage Management Appliance is a host-independent system that performs management functions without requiring host computers. |
|
|
|
| Feature List |
|
|
|
|
| Customer Benefits |
|
|
|
|
| Software Features/ Functionality |
HP OpenView Storage
Management Appliance software v2.1 The web-based interface for storage management HP OpenView Storage Management Appliance software v2.1 is a centralized, appliance-based monitoring and management interface for the Open SAN. Storage Management Appliance software provides a web-based aggregation and entry point for centralized storage management. This intuitive interface allows the user to organize, visualize, configure and monitor storage from a single navigation point on the SAN. It provides a launch site for a variety of value-added HP storage management applications as well as popular data and virus protection products, and provides navigation links to directly manage storage devices. |
|
| HSG Element Manager v1.0f.3
(Storage Management Appliance software v2.1 Service Pack 1) |
HSG Element Manager is an easy to use, graphical storage configuration and monitoring tool for HSG80/60 storage that centralizes SAN management across network and multi-vendor platforms. Included with the Storage Management Appliance software, HSG Element Manager reduces the job of storage management to simple point-and-click, across the switched Fibre Channel SAN. Features include:
*NOTE: SMI-S components are provided separately and are specific to the version of HSG Element Manager. They are available from the Web at: http://h18000.www1.hp.com/products/sanworks/softwaredrivers/ managementappliance/index.html#snia |
|
| Command View EVA (sold separately) |
HP StorageWorks Enterprise Virtual
Array Media (XCS and VCS) provides storage controller software capability
for the HSV1xx and HSV2xx-based Array Controllers. Dual redundant HSVxxx
Array Controllers are configured into the StorageWorks Enterprise Virtual
Array (EVA), HP's high performance, high capacity, and high availability
"virtual" RAID (Vraid) storage solution.
VCS is managed through Command View EVA, a device management application with a graphical user interface that runs on the Storage Management Appliance or a general purpose server and is accessed via a Web browser. The number of EVA arrays supported depends on the EVA management deployment option of choice. While the Storage Management Appliance supports 16 EVA arrays, support with other Command View EVA deployment options may vary. Please see the Command View EVA v4.1 QuickSpecs for the latest number of EVAs supported for the desired deployment option. HP StorageWorks Command
View EVA offers a SNIA SMI-S provider for EVA. The SMI-S components for
Command View EVA are provided separately through HP StorageWorks SMI-S
EVA providers in the Command View EVA media kit. |
|
| Automation Manager | Automation Manager provides an infrastructure that enables storage administrators to implement automated storage management solutions in their enterprise. This infrastructure supports policy-based automation for tasks and job scheduling for a heterogeneous set of platforms through the use of host agents. Proactive, automated responses can be defined for storage hardware-based events monitored by the Storage Management Appliance using customizable or user-defined scripts. Scripts are easily customized with the graphical user interface provided. Automation Manager is included with HP OpenView Storage Management Appliance software v2.1. | |
|
|
||
| Guidelines for managing HSG and HSV controller pairs | |||||||||||
| The following guidelines apply to the combined maximum number of controller pairs managed by Command View EVA (HSV1xx and HSV2xx controller pairs) and HSG Element Manager (HSG controller pairs) with one Storage Management Appliance: | |||||||||||
|
|||||||||||
| NOTE: The number
of EVA arrays supported depends on the EVA device management deployment
option of choice. While the Storage Management Appliance continues to support
16 EVA arrays, support with other Command View EVA deployment options may
vary. Please see the Command View EVA v4.1 QuickSpecs for the latest number
of EVA supported for the desired deployment option. NOTE: HP StorageWorks Continuous Access EVA v1.1 and later requires Command View EVA v3.1 or later which is included with HP OpenView Storage Operations Manager (v3.1, 3.2, 3.3) or the HP StorageWorks Command View EVA software suite (v4.0 or later). Please refer to the respective product QuickSpecs for more detailed support information. Command View EVA is sold separately from the Storage Management Appliance. |
|
|
| Software Prerequisites | ||
| HP OpenView Storage Management Appliance software. Factory-installed version included with hardware; updates are orderable from the Web at: http://h18006.www1.hp.com/products/sanworks/softwaredrivers/managementappliance/index.html. | ||
| Automation Manager software prerequisites |
|
|
|
|
||
| Storage Management Appliance Supported Browsers* |
|
Operating System
|
Browser
|
|
Microsoft Windows 2000 Server and Advanced Server SP4
(32 bit)
|
IE 6.0 (SP1)
|
|
Microsoft Windows Server 2003 Enterprise Edition and
Standard Edition (IA32)
|
IE 6.0 (SP1)
|
|
Microsoft Windows 2000 Professional
|
IE 6.0 (SP1)
|
|
Microsoft Windows XP Professional
|
IE 6.0 (SP1)
|
|
HP-UX PA-RISC 11.11/11i V1 (64 bit)
|
Mozilla 1.7.3
|
|
HP-UX 11.23 PI64
|
Mozilla 1.7.3
|
|
Red Hat Enterprise Linux Advanced Server v3.0 (IA32)1
|
Mozilla 1.7.3
|
|
Sun Solaris 9
|
Mozilla 1.7.3
|
|
IBM AIX v5.31
|
Mozilla 1.7.3
|
|
HP Tru64 v5.1b1
|
Mozilla 1.7.5
|
|
HP OpenVMS1 v7.3-2
|
Mozilla 1.7
|
|
HP OpenVMS1 v8.2
|
Mozilla 1.7
|
| Legend IE = Internet Explorer NN = Netscape Navigator | ||
| 1
Not supported for use with HSG Element Manager * Storage Management Appliance software does not employ JRE support. However, certain layered software supported on the Storage Management Appliance are JRE-enabled. Please ensure you refer to the Product QuickSpec for each layered software product to ensure you are using the appropriate version of JRE with your browser to ensure support. NOTE: Supported layered software products may have certain browser restrictions not reflected in this matrix. Ensure that you read and understand the Release Notes for each product before using. |
||
| |
| Supported Hardware Devices | Storage Arrays | HP StorageWorks Enterprise Virtual Array, all models running VCS v3.014 or greater*** |
| HP StorageWorks Enterprise Modular Array 16000 Fibre Channel running ACS 8.6 or greater | ||
| HP StorageWorks Enterprise Storage Array 12000 Fibre Channel running ACS 8.6 or greater | ||
| HP StorageWorks Enterprise Modular Array 12000 Fibre Channel running ACS 8.6 or greater | ||
| HP StorageWorks Modular Array 8000 Fibre Channel running ACS 8.6 or greater | ||
| HP StorageWorks Modular Array 6000 Fibre Channel running ACS 8.6 or greater | ||
| Interconnect Devices | HP StorageWorks SAN Switch 2/32 | |
| HP StorageWorks SAN Switch 2/16 | ||
| HP StorageWorks SAN Switch/8 & /16 | ||
| HP StorageWorks SAN Switch 2/8V* | ||
| HP StorageWorks SAN Switch 2/16V* | ||
| HP StorageWorks SAN Switch 2/16N* | ||
| HP StorageWorks SAN Director 2/128* | ||
| HP StorageWorks SAN Switch 2/32* | ||
| HP StorageWorks SAN Switch 2/8-EL & 2/16-EL | ||
| HP StorageWorks SAN Switch 8-EL & 16-EL | ||
| HP StorageWorks SAN Switch Integrated/32 & 64 (1 Gb/s) | ||
| HP StorageWorks Core Switch 2/64 | ||
| Brocade Silkworm 2400, 2800, 2050, 2250, 6400, 6432 | ||
| Brocade Silkworm 12000, 3200, 3250*, 3600, 3800, 3850*, 24000* | ||
| HP StorageWorks Fibre Channel Arbitrated Loop Switch 8 (FC-AL)* | ||
| HP StorageWorks Director 2/140* | ||
| HP StorageWorks SAN Director 64 | ||
| HP StorageWorks Director 2/64 | ||
| HP StorageWorks Edge Switch 2/32, 2/24*, 2/16, 2/12* | ||
| McData ED-6064 Director (1 Gb/s) | ||
| McData ED-6064 Director (2 Gb/s) | ||
| McData ED-6140 Director | ||
| McData ED-5000 Director | ||
| McData ES-3016, ES-3216 | ||
| McData ES-3032, ES-3232 | ||
| McData ES-4300* | ||
| McData ES-4500* | ||
| Cisco MDS 9506 Director Switch** | ||
| Cisco MDS 9509 Multilayer Director** | ||
| Cisco MDS 9216 Multilayer Fabric Switch** | ||
| Cisco MDS 9216A Multilayer Fabric Switch** | ||
| Cisco MDS 9216i Multilayer Fabric Switch** | ||
| Cisco MDS 9120 Fabric Switch** | ||
| Cisco MDS 9140 Fabric Switch** | ||
| HP StorageWorks Modular Data Router II & III* | ||
| NAS Devices | HP StorageWorks NAS e7000* | |
| HP StorageWorks NAS b3000* | ||
| HP StorageWorks NAS b2000* | ||
| HP StorageWorks NAS n2400* | ||
| Network Appliance F700 & F800 series filers | ||
| *NOTE: These
devices are supported by a subset of Storage Management Appliance software v2.1 event management and notification features. **NOTE: Cisco switch support requires an update to Storage Management Appliance software v2.1 Service Pack 2. This Service Pack may be downloaded from http://h18006.www1.hp.com/products/sanworks/softwaredrivers/ managementappliance/index.html ***NOTE: VCS v3.014 and greater include some EVA events not supported through the SMA software event management system. Customers using VCS v3.014 or higher are recommended HP Storage Essentials, , HP Systems Insight Manager and/or HP Storage Node Manager for EVA event management and notification to ensure all events are reported properly. |
||
|
|
||
| Supported Layered Software |
|
| NOTE: Supported
layered software products may have certain interoperability restrictions.
Ensure that you read and understand all Documentation and Release Notes
for each product before you install them on your Storage Management Appliance.
NOTE: HP only supports those software products that have been tested and qualified by HP Labs. Software not listed on this Supported Layered Software list will not be supported by HP if installed directly on a Storage Management Appliance. 3. Command View EVA and Storage Operations Manager include the appropriate version of SMI-S provider for EVA. 4. Continuous Access EVA v1.1, v1.1a, v1.2, and v2.0 requires HP OpenView Storage Operations Manager, which is purchased separately from the Storage Management Appliance. Continuous Access EVA v2.1 requires HP StorageWorks Command View EVA v4.0 or later. See the Continuous Access EVA product QuickSpecs for more detailed information. 5. Hardware restrictions apply. Storage Management Appliance I not supported; Storage Management Appliance II requires 1 GB RAM upgrade (HP part number 201694-B21); Storage Management Appliance III supported as is. 6. Customers who are adding new Enterprise Virtual Arrays for the first time, or customers that are upgrading to VCS v3.020 or later should contact their HP authorized service representative for more information on proactive event notification services in their area. |
|
|
| |
| Software Distribution Media | HP OpenView Storage Management
Appliance software v2.1 is included with a new Storage Management Appliance
III purchase. Current customers may order an update CD-ROM and hardcopy documentation set from the Web at: http://h18006.www1.hp.com/products/sanworks/softwaredrivers/managementappliance/index.html. Web downloads for service packs are made available for current Storage Management Appliance customers at: http://h18006.www1.hp.com/products/sanworks/softwaredrivers/managementappliance/index.html |
|
|
Models
| Storage
Management Appliance III 189715-003 | Processor | (1) Intel Xeon 2.40 GHz Processor |
| Cache Memory | 512 KB level 2 ECC cache | |
| Memory | 2 GB 2-way interleaved PC2100 DDR SDRAM running at 266MHz, Advanced ECC | |
| Fibre Channel Adapter | HP FCA2355 1Gb / 2Gb dual-port PCI Fibre Channel HBA | |
| Network Controller | 2 NC7781 PCI-X Gigabit NICs 10/100 (embedded) | |
| Hard Drive | Two 72.8 GB Ultra320 SCSI 10,000 rpm Hard Drives (1") | |
| Optical Drive | Slim Line DVD-ROM Drive (8x/24x) | |
| Form Factor | Rack (1U), (1.75-inch). Supported in the 9000, 10000, Millennium, and eSeries series rack environments. |
|
|
Standard Features
| Processor | Intel Xeon 2.40 GHz Processor |
|
|
|
| Memory | Standard | 2 GB (2-way interleaved PC2100 DDR SDRAM running at 266MHz, Advanced ECC memory) |
|
|
||
| Network Controller | Two NC7781 PCI-X Gigabit NICs 10/100 |
|
|
|
| Expansion Slots | I/O (1 Total, 0 available) | ||
| 64-bit/100MHz PCI-X | 1 | HP FCA2355 | |
|
|
|||
| Storage | Diskette Drives | 1.44 MB | |
| CD-ROM | Slim Line DVD-ROM Drive (8x/24x) | ||
| Hard Drives | 145.6 GB (2 x 72.8 GB 1" Ultra320) (internally mirrored) | ||
|
|
|||
| Interfaces | Serial | 1 | Service |
| Pointing Device (Mouse) | 1 | Optional for Diagnostic & Set-up | |
| Graphics | 1 | Optional for Diagnostic & Set-up | |
| Keyboard | 1 | Optional for Diagnostic & Set-up | |
| Network RJ-45 | 2 | Network Portal | |
| USB | 2 | Not Used | |
|
|
|||
| Form Factor | Rack (1U), (1.75 inch) |
|
|
|
| HP Server Essentials Software | HP System Management Homepage | The System Management
Homepage helps systems administrators rapidly respond to potential and actual
system failures, increase system stability, and reduce troubleshooting complexity
for individual HP ProLiant and Integrity servers. It provides a consolidated
view of all system health and configuration information and simplifies access
to HP web-enabled system management software running, such as Insight Management
Agents and Diagnostics. The System Management Home Page can be accessed directly through a secure web browser or indirectly through HP Systems Insight Manager, Insight Manager 7 SP2, OpenView Operations, OpenView Network Node Manager, or third party enterprise management tools such as CA Unicenter, Tivoli Enterprise Console or Microsoft Operations Manager. For additional information about the Insight Management Agents and other HP management products for HP servers, please visit the management Web site at: http://h18000.www1.hp.com/products/servers/management/agents/ description.html |
|
|
|
|||
| Industry Standard Compliance | ACPI 1.0b compliant |
| PCI 2.2 compliant | |
| Microsoft Logo certifications | |
|
|
|
| Power Supply | 325-Watt hot plug power supply, with 1+1 redundancy, Universal Voltage |
|
|
|
| Required Cabling | HP OpenView Storage Management Appliance III requires an appropriate LC interconnect cable for connection to the SAN. |
| | |
| Space Requirements |
|
|
|
|
| Power Requirements |
|
|
|
|
| Grounding Requirements | For proper operation and safety, the equipment must be properly grounded in accordance with NFPA 70-1993, Article 250. All power distribution devices, branch wiring, and receptacles must be "Listed" grounding-type devices. When using power strips for electrical distribution, make sure that ground integrity is maintained for each connection made. Plug each component into a reliably grounded outlet. |
|
|
|
| Airflow Requirements |
|
| | |
| OS Support | HP OpenView Storage Management
Appliance software (a factory-installed version included) Software Update CD's and downloadable Service Packs available from the Web at: http://h18000.www1.hp.com/products/sanworks/softwaredrivers/managementappliance/index.html. |
|
|
Service and Support, HP Care Pack, and Warranty Information
| Software Licensing | Hewlett-Packard Company grants the right to the use of the HP OpenView Storage Management Appliance (hardware and base software contained on the Storage Management Appliance) with purchase. |
|
|
|
| Warranty |
NOTE: Certain restrictions and exclusions apply. Consult the HP Customer Support Center for details. |
|
|
|
| Software Product Services Included with the Product | Included with the purchase of the product is three year software support service that includes 24 x 7 technical software phone-in. |
|
|
|
| Command View EVA Installation and Start-up Service |
The Command View EVA Installation and Start-up Service is not included with the purchase of HP OpenView Storage Management Appliance. It is included with the purchase of HP OpenView Storage Operations Manager or HP StorageWorks Command View EVA software suite. It also remains a separate offering for customers purchasing a Storage Management Appliance for redundant configurations. It includes:
For additional information please refer to URL: http://www.hp.com/hps/ |
|
|
|
| Additional Storage Service Offerings |
For information on the full suite of Storage Services offered by HP please
refer to URL: |
|
|
Storage
|
|
0, 1 |
2 1 inch Wide Ultra320 Hot Pluggable Hard Drive Bays |
|
A |
1.44-MB Diskette Drive (fixed) | |
|
B
|
Slim Line DVD-ROM Drive (8x/24x) (ejectable) | |
|
Drive Support |
||||
|
|
||||
|
Quantity |
Position |
|
||
|
Removable Media |
||||
| 1.44 MB Diskette Drive | Up to 1 | A | Integrated | |
| IDE DVD-ROM Drive | Up to 1 | B | Integrated IDE | |
|
|
||||
|
Hard Drives |
||||
| Ultra320 Hot Pluggable Drives | ||||
| 72.8 GB 10,000 rpm | 2 | 0, 1 | Smart Array 5i plus Controller (integrated on system board) | |
|
|
Technical Specifications
| System Unit | Dimensions (HxWxD) | 1.70 x 16.78 x 27.25 in (4.32 x 42.62 x 69.22 cm) | |
| Weight | Maximum | 37 lb (16.78 kg) | |
| No drives | 27.5 lb (12.47 kg) | ||
|
Input Requirements (per power supply) |
Range Line Voltage | 100 to 240 VAC | |
| Nominal Line Voltage | 100 to 120 VAC/200 to 240 VAC | ||
| Rated Input Current | 5A (100VAC) to 2.5A (200VAC) | ||
| Rated Input Frequency | 50 to 60 Hz | ||
| Rated Input Power | 450 W (100VAC) NOTE: 450 W of Rated Input Power is for the Maximum Peak Output Power of 325 W. |
||
| BTU Rating | 1535 BTUs/hr NOTE: The BTU rating listed is for the Rated Input Power of 325 W. |
||
| Power Supply Output Power (per power supply) | Rated Steady-State Power | 325 W | |
| Maximum Peak Power | 325 W | ||
| Temperature Range | Operating | 50° to 95° F (10° to 35° C) | |
| Shipping | -22° to 122° F (-30° to 50° C) | ||
| Relative Humidity (non-condensing) |
Operating | 8% to 90% | |
| Shipping | 5% to 95% | ||
| Acoustic Noise | Idle (Fixed Disk Drives Spinning) |
||
|
L WAd (BELS)
|
6.5 | ||
|
L pAm (dBA)
|
51 | ||
|
Operating
(Random Seeks to Fixed Disks) |
|||
|
L WAd (BELS)
|
7.6 | ||
|
L pAm (dBA)
|
59 | ||
|
|
|||
|
1.44-MB Diskette Drive |
Diskette Size |
3.5 in |
|
| LED Indicators (front panel) | Green | ||
| Read/Write Capacity per Diskette (high/low density) | 1.44 MB/720 KB | ||
| Drives Supported | One | ||
| Drive Height | 11 mm | ||
| Drive Rotation | 300 rpm | ||
| Transfer Rate (high/low) | 500/250 Kb/s | ||
| Bytes/Sector | 512 | ||
| Sectors/Track (high/low) | 18/9 | ||
| Tracks/Side (high/low) | 80/80 | ||
|
Access Times |
Track-to-Track (high/low) |
3/6 ms |
|
|
Average (high/low) |
94/169 ms |
||
|
Settling Time |
15 ms |
||
|
Latency Average |
100 ms |
||
|
Cylinders (high/low) |
80/80 |
||
|
Read/Write Heads |
Two |
||
|
|
|||
|
SCSI Hard Drives |
72.8-GB 10,000 rpm U320 Universal Hard Drive (1") | Capacity | 72837.2 MB | |
| Height | 1.0 in (2.54 cm) | |||
| Width | 4.0 in (10.16 cm) | |||
| 286722-B21 | Interface | Ultra320 SCSI | ||
| Transfer Rate Synchronous
(Maximum) |
320MB/s | |||
| Seek Time (typical
reads, including settling) |
Single Track | 0.55 ms | ||
| Average | 4.9 ms | |||
| Full-Stroke | 10.0 ms | |||
| Rotational Speed | 10,000 rpm | |||
| Physical Configuration | Bytes/Sector | 512 | ||
| Logical Blocks | 142,264,000 | |||
| Operating Temperature | 50° to 95° F (10° to 35° C) | |||
|
|
||||
| Slim Line DVD-ROM Drive (8x/24x) | Disk 267985-B21 |
Applicable Disk | DVD-ROM |
| DVD-R (Read Only) | |||
| 4.7GB/side DVD-RAM (Read Only) | |||
| 2.6 GB/side DVD-RAM (Read Only) | |||
| CD-ROM Mode-1 data disc | |||
| CD-ROM Mode-2 data disc | |||
| CD Audio disc | |||
| CD-Extra | |||
| CD-RW (Read Only) | |||
| CD-R (Read Only) | |||
| CD Text | |||
|
Capacity |
DVD-ROM DVD-SL/SS (DVD-5) 4.7 GB/per side | ||
| DVD-ROM DVD-DL/SS (DVD-9) 8.5 GB/per side | |||
| DVD-ROM DVD-DS/SL (DVD-10) 9.4 GB/per side | |||
| DVD-ROM DVD-DS/DL (DVD-18) 17.1 GB/per side | |||
| DVD-R 3.95 GB/side | |||
| DVD-RAM 2.6 GB/side | |||
| DVD-RAM 4.7 GB/side | |||
| CD-ROM Mode-1 650 MB | |||
| CD-ROM Mode-2 742 MB | |||
| Diameter | 120 mm, 80 mm (with adapter at vertical mounting mode | ||
| Block Size | Mode 1 | DVD 2,048 bytes | |
| Mode 2 | CD 2,336 bytes | ||
| Interface | IDE (ATAPI) | ||
| Access Times (typical) |
Random |
DVD-ROM < 150 ms, CD-ROM < 100 ms | |
|
Full-Stroke |
DVD-ROM < 240 ms, CD-ROM < 225 ms | ||
| Data Transfer Rate | Sustained (DVD) | 10.8 MB/sec | |
| Sustained (CD) | 3.6 MB/sec | ||
| Cache Buffer | 256 KB | ||
| Start-up Time (typical) | 19 seconds or less | ||
| Operating Conditions | Temperature | 41° to 113° F (5° to 45° C) | |
| Humidity | 15% to 85% | ||
| Dimensions | (HxWxD, maximum) | 0.5 x 5.04 x 5.09 in (1.27 x 12.80 x 12.94 cm) | |
| Weight | 1.50 lb (0.68 kg) | ||
|
|
|||
|
(2) NC7781 PCI-X Gigabit NICs (embedded) |
Network Interface | 10/100/1000-T | |
| Compatibility | IEEE 802.3 10Base-T | ||
| IEEE 802.3ab 1000Base-T | |||
| IEEE 80.3u 100Base-TX | |||
| Data Transfer Method | 64-bit/133MHz PCI-X | ||
| Network Transfer Rate | 10Base-T(Half-Duplex) | 10 Mb/s | |
| 10Base-T(Full-Duplex) | 20 Mb/s | ||
| 100Base-TX(Half-Duplex) | 100 Mb/s | ||
| 100Base-TX(Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Half-Duplex) | 1000Mb/s | ||
| 1000Base-TX (Full-Duplex) | 2000 Mb/s | ||
| Connector | RJ-45 | ||
| Cable Support | 10Base-T | Category 3,4 or 5 UTP up to 328 ft (100 m) | |
| 10/100/1000Base-TX | Category 5 UTP up to 328 ft (100 m) | ||
|
|
|||
| HP FCA2355 | FC Link | 1Gb/2Gb | |
| Network Transfer Rate | 1.0625 Gb/s, 2.125 Gb/s | ||
| Connector | LC interface | ||
| Distance | 1 Gb/s | 500 m (1640') 50/125 um fiber | |
| 300 m (984') 62.5/125 um fiber | |||
| 2 Gb/s | 300 m (984') 50/125 um fiber | ||
| 150 m (492') 62.5/125 um fiber | |||
| Operating Conditions | Temperature | 32° to 113° F (0° to 45° C) | |
| Humidity | 5% to 95% non-condensing | ||
|
|
|||
| Rack Mounts | Standard Included | Includes hardware to mount into 9000, 10000, Millennium, and System/E Racks |
| | ||
| Filler Panels | Required for System/ E Rack |
Filler panels must be ordered for mounting into System/E Rack:
|
| | ||
| Power Cords | Standard Included | X2 CORDS, AC, IEC-IEC, 10FT |
142263-007
|
|
|
|||
|
© Copyright 2003-2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |