|
|
Overview
|
HP StorageWorks 2000sa G2 Modular Smart Array |
|
The HP StorageWorks 2000sa G2 Modular Smart Array is a 3Gb SAS direct
attach, external shared storage solution that helps customers easily transition
from direct attached to centralized storage. It allows departmental and
small to medium businesses customers to grow capacity as demands increase
up to 29.7 TB SAS or 60 TB SATA, and supporting up to 64 hosts |
|
| What's New |
|
|
|
![]() |
| HP StorageWorks 2024 G2 Modular Smart Array |
![]() |
| HP StorageWorks 2012 G2 Modular Smart Array |
|
|
Models
|
Models
|
||
| HP StorageWorks 2000sa G2 Modular Smart Array | Controller-less CHASSIS & MSA2300sa G2 Controller | |
| HP StorageWorks 2012 Modular Smart
Array 3.5-in Drive Bay Chassis (LFF) (Will accept one or two controllers or Disk Enclosure I/O modules) |
AJ948A | |
| HP StorageWorks 2024 Modular Smart
Array 2.5-in Drive Bay Chassis (SFF) (Will accept one or two controllers) |
AJ949A | |
| HP StorageWorks 2300sa G2 Modular Smart Array Controller | AJ808A | |
| Disk Enclosures | ||
| HP StorageWorks MSA2000 Single
I/O 3.5-inch 12 LFF Drive Enclosure (w/ two .6m SAS to SAS cables) Used with single controller array head |
AJ749A | |
| HP StorageWorks MSA2000 Dual I/O
3.5-inch inch 12 LFF Drive Enclosure (w/ two .6m SAS to SAS cables) Used with dual controller array head |
AJ750A | |
| HP StorageWorks MSA2000 Drive
Enclosure I/O Module (no cable included) |
AJ751A | |
| HP StorageWorks MSA70 2.5-inch
25 SFF Drive Enclosure 2.5 in Drive Enclosure (single I/O, single domain) (w/one .5m miniSAS to miniSAS cable) |
418800-B21 | |
| HP StorageWorks Dual Domain I/O
Module for MSA70 enclosure (upgrades MSA70 to dual domain) (w/ one .5m miniSAS to miniSAS cable) |
AG779A | |
| Configured Units | ||
| HP StorageWorks 2312sa G2 Dual Controller Modular Smart Array (LFF) | AJ805A | |
| HP StorageWorks 2324sa G2 Dual Controller Modular Smart Array (SFF) | AJ807A | |
| Controller-less Chassis: DC-powered units | ||
| HP StorageWorks 2012 Modular Smart Array 3.5-in Drive Bay DC-power Chassis (LFF) (can add one or two MSA2300sa G2 controllers or MSA2000 JBOD I/O modules) | AJ950A | |
| HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay DC-power Chassis (SFF) (can add one or two MSA2300sa G2 controllers. No MSA2000 JBOD I/O module support) | AJ951A | |
| Controller-less Carrier Grade Chassis | ||
| HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay Carrier-Grade Chassis (SFF) | AM337A | |
| Related Option | ||
| HP StorageWorks 2000sa Modular
Smart Array Controller (limited use) (for use only with an AJ948A LFF chassis for those needing to configure an older MSA2012sa. Only supports older features, functionalities. No SFF or MSA70 JBOD support, max 48 LFF drives, max 64 snaps) |
AJ754A | |
|
Related Items
|
||
| MSA2324sa G2 DL380 G6 Package Cluster | HP StorageWorks 2324sa G2 Modular
Smart Array DL380 G6 Package Cluster NOTE: The HP MSA2324sa G2 DL380 G6 Package Cluster Bundle contains the following components: One MSA2324sa G2 Dual-controller array; Two DL380 G6 Servers Four HBAs Four SAS cables Snapshot software 8 LTU (NOTE: This bundle is available worldwide except APJ and Brazil) |
AP813A |
| MSA2000sa Switch Bundle |
HP StorageWorks 2000sa Modular Smart Array 3Gb SAS BL Switch Bundle
NOTE: This bundle includes original MSA2000sa controllers |
AP716A |
| 3Gb SAS Switch |
HP StorageWorks 3Gb SAS BL Switch (CTO Only) |
AJ864A |
| HP StorageWorks 3Gb SAS BL Switch - Dual Pack | AJ865A | |
|
Configuration Rules:
|
||
| Blade Mezzanine Module | HP Smart Array P700m Controller/256BBWC Controller | 507925-B21 |
| HP Smart Array P700m Controller/512 BBWC Controller | 508226-B21 | |
| Battery Kit | 452348-B21 | |
|
Configuration Rules:
|
||
|
|
Features and Benefits
| Key Hardware Features |
|
|
|
| Customer Benefits |
|
|
|
At a Glance
| HP MSA2000sa G2 At a Glance: |
|
|
|
Family Information
| MSA2000sa G2 | MSA2000fc G2 | MSA2000i G2 | ||||
| Capacity (raw) Minimum / with maximum additional drive enclosures |
LFF: | 5.4 TB SAS or 12 TB SATA w/ 4 drive enclosures: 27 TB SAS or 60 TB SATA |
LFF: | 5.4 TB SAS or 12 TB SATA w/ 4 drive enclosures: 27 TB SAS or 60 TB SATA |
LFF: | 5.4 TB SAS or 12 TB SATA w/ 4 drive enclosures: 27 TB SAS or 60 TB SATA |
| SFF: | 7.2 TB SAS or 6.0 TB SATA w/ 3 MSA70 JBODs: 29.7 TB SAS or 24.7 TB SATA |
SFF: | 7.2 TB SAS or 6.0 TB SATA w/ 3 MSA70 JBODs: 29.7 TB SAS or 24.7 TB SATA |
SFF: | 7.2 TB SAS or 6.0 TB SATA w/ 3 MSA70 JBODs: 29.7 TB SAS or 24.7 TB SATA |
|
| Controller Cache | 1 GB per controller | 1 GB per controller | 1 GB per controller | |||
| Total LUNs | 511 | 512 | 512 | |||
| Host connect MSA2000 has 1 or 2 controllers, EVA has 2 controllers standard |
Four 3Gb SAS ports per controller |
Two 4Gb Fibre Channel ports per controller |
Two 1GbE iSCSI ports per controller |
|||
| Maximum Drives w/ expansion |
60 LFF/99 SFF | 60 LFF/99 SFF | 60 LFF/99 SFF | |||
| Maximum host supported | 64** | 64 | 32 | |||
| Snapshot, remote replication | Snapshot, clone | Snapshot, clone | Snapshot, clone | |||
| Use for Storage | Primary Storage with SAS Secondary with SATA | Primary Storage with SAS Secondary with SATA | Primary Storage with SAS Secondary with SATA | |||
| *maximum available storage
capacity depends on the RAID level being implemented, and is based on maximum
number of LUNs and LUN size ** Supports up to 8 hosts with SAS direct connect and 64 hosts (BladeSystem servers) using 3Gb SAS BL switch |
|
|
|
Product Technology |
SAS | Four 3Gb host ports per controller |
| Modular Chassis | 2U rack height. 12 Large Form Factor or 24 Small Form Factor drive bays, accommodating SAS and SATA. Comes with space for one or two controllers, or MSA2000 3.5-inch disk Enclosure I/O modules (LFF chassis only). | |
| Drives available | The new MSA2300sa G2 controller
supports both the MSA2 3.5-inch Large Form Factor (LFF) drives, or the HP
ProLiant 2.5-inch Small Form Factor (SFF) drive Serial Attached SCSI (SAS) enterprise-class drives designed for high volume, 24x7 usage. Serial-ATA (SATA) are usually reserved for archival of data as they are both relatively inexpensive and are available in very large capacities. The MSA2000 family of arrays can accommodate both SAS and SATA drives within the same enclosure making it ideal to have both business-critical, high activity files on SAS drives while using snapshot or clone capability to keep back-up data on the less expensive drives. For investment protection, the MSA2300sa G2 controller will support single port SAS & SATA drives in a single-domain MSA70. This support allows current owners of MSA70s to migrate their single port drives (in their MSA70 only) to be attached to an MSA2000sa G2. They can only cascade to another single I/O MSA70. This is not a data-in-place transition. SAS drive performance can be approximately 30% greater than SATA performance on sequential host IO. SAS performance excels in sequential lower latency response time and random IO per second transaction performance due to higher rpm disk speeds yielding lower seek times. NOTE: MSA2 3.5" Large Form Factor (LFF) drives are for use only in the MSA2000 family. |
|
| Optional Disk enclosures |
Just as the user has a choice of chassis for the array head (LFF and SFF drive bays), so also do they have a choice of expansion disk enclosures accommodating either drive size. (NOTE: these are not supported as part of a NEBS-certified with the MSA Carrier Grade Chassis.) |
|
|
MSA2000 3.5-inch drive enclosure. This 2U unit has twelve LFF (3.5-inch) drive bays and accepts for MSA2 dual-ported SAS and SATA drives. One model (AJ749A) has a single I/O module that matches with a single controller array head, giving a single path to the drives. The second model (AJ750A) comes standard with two I/O modules installed, required when paired with a dual controller array head, giving two paths to the drives for higher availability.
|
||
|
MSA70 2.5-inch drive enclosure. This 2U storage enclosure (418800-B21) is designed to support twenty five ProLiant 2.5-inch Universal form factor (SFF) SAS or SATA hard drives. It ships standard with a single I/O module installed.
|
||
| Scalability |
The MSA2300sa G2 controller is designed to allow an installation to begin with smaller capacity and be able to grow gradually as needed. The flexibility of SAS or SATA drive technology, form factors, sizes, speeds, and costs per GB allows a system to easily fit in almost any budget.
Qualification of larger capacity drives is ongoing. |
|
| LUNs | The MSA2000 family of arrays supports 511 LUNs and LUN sizes up to 16TB. The arrays support LUN expansion and deletion of any LUN. | |
| RAID 0, 1, 3, 5, 6, 10, 50 | In addition to the usual RAID levels, the MSA2000 family features several important additional levels. RAID 6 is the highest level of RAID protection. It allocates two sets of parity data across drives and allows simultaneous write operations. It can withstand two simultaneous drive failures without downtime or data loss. RAID 10 is mirroring and striping without parity. It is the most popular of the multiple RAID levels, allowing large arrays with high performance in most cases and superior fault tolerance. RAID 50 combines the block striping and parity of RAID 5 with the straight block striping of RAID 0, yielding higher performance than RAID 5 through the addition of RAID 0, particularly during writes. | |
| Configuration and Management Tools | HP StorageWorks MSA Storage Management Utility (SMU), Management access, out-of-band: WEB GUI, CLI. Interface Types: Mini DB9 RS232, 10/100 Ethernet Protocols Supported SNMP, SSL, SSH, SMTP, HTTP, Telnet. | |
| Hot Plug Expansion and Replacement Support | The MSA2000sa G2 supports hot plug expansion and replacement of redundant controllers, fans, power supplies, and I/O modules for simple, fast installation and maintenance. | |
| Snapshot and Clone | Optional controller based functionality. Offers higher levels of data protection, enabling an almost instant recovery from data failure or corruption. Offers alternative development testing of 'offline' production data and the ability to backup snapped/cloned data. | |
| Performance | Performance numbers are a guideline
as established by tests using RAW I/O in an Operating System Agnostic test
lab environment. A total of 96 72GB 15K SAS drives were used in a dual controller
configuration of eight 12 Disk vdisks, eight 806 GB volumes, and two volumes
per host. Four hosts directly attached to the MSA2000sa G2 were used in
this test configuration (results cannot be expected with a single host).
Results were achieved in Sequential Writes with 256K blocks; all random
test were based on 8K block sizes. Number and type of applications, drive type, operating system used, and the number of hosts will affect overall performance. |
|
| Workload |
MSA2300sa G2
|
|
| Host Connect | 3Gb SAS | |
| MSA2000 RAID 10 Performance Results (rounded) | ||
| Random Reads IOPs |
21861
|
|
| Random Writes IOPs |
14491
|
|
| Random Mix IOPs 60/40 read/write |
17700
|
|
| Sequential Reads MB |
1049
|
|
| Sequential Writes MBs |
531
|
|
| MSA2000 RAID 5 Performance Results (rounded) | ||
| Random Reads IOPs |
21019
|
|
| Random Writes IOPs |
2705
|
|
| Sequential Reads MBs |
1051
|
|
| Sequential Writes MBs |
644
|
|
| Random Mix IOPs 60/40 read/write |
5897
|
|
| MSA2000 RAID 6 Performance Results (rounded) | ||
| Random Reads IOPs |
21029
|
|
| Random Writes IOPs |
1918
|
|
| Sequential Reads MBs |
1054
|
|
| Sequential Writes MBs |
736
|
|
| Random Mix IOPs 60/40 read/write |
4872
|
|
| Overview | The MSA2000sa G2 comes integrated with web browser based software for storage and RAID management, setup, configuration and troubleshooting. This reduces the cost of ownership by reducing the training and technical expertise necessary to install and maintain your HP storage solution. |
| Server Compatibility |
Supports most HP ProLiant servers including:
Following BladeSystem servers are supported ONLY when connected using 3Gb SAS Switch:
|
| Industry Standard X86 servers support |
|
| OS Support |
NOTE: For detail operating support list, please visit: www.hp.com/storage/spock |
| Supported Clustering Solutions |
|
| Application Solutions |
The MSA is the ideal solution for small and midsized business customers
running Oracle, Microsoft, SAP, VMware, and Xen environments. The MSA
offers these customers an affordable, scalable solution that will grow
as business needs change. The MSA is flexible offering customers the choice
of FC, SAS, or iSCSI host connections.
|
| Learn More | To learn more about specific HP Storage Solutions
that are built with Oracle, Exchange, SAP environments in mind, visit the
solution sites supporting each of these applications. HP Storage for Oracle hyperlink to: http://www.hp.com/storage/oracle HP Storage for Microsoft SQL Server hyperlink to: http://www.hp.com/storage/sqlserver HP Storage for Microsoft Exchange hyperlink to: http://www.hp.com/storage/exchange HP Storage for SAP hyperlink to: http://www.hp.com/storage/sap |
| Web Browser support |
|
|
|
Optional Software
|
Optional Software |
|||
| MSA2300 Snapshot and Volume Copy Software | Product Features | ||
|
Data Protection
|
|||
|
Data Testing
|
|||
| HP StorageWorks 2000 Modular Smart Array Snapshot 255 Software LTU1 |
T5539A
|
||
| HP StorageWorks 2000 Modular Smart Array Snapshot 64 Software LTU |
T5512A
|
||
| HP StorageWorks 2000 Modular Smart Array Snapshot 8 Software LTU |
T5513A
|
||
| HP StorageWorks 2000 Modular Smart Array Snapshot 8/255 Upgrade Software LTU1 |
T5540A
|
||
| HP StorageWorks 2000 Modular Smart Array Snapshot 64/255 Upgrade Software LTU1 | T5541A | ||
| HP StorageWorks 2000 Modular Smart Array Snapshot 8 to 64 Upgrade Software LTU | T5515A | ||
| HP StorageWorks 2000 Modular Smart Array Volume Copy Software LTU | T5514A | ||
| 1 The snapshot software is supported on the MSA2324 and MSA2312 (G2) models only | |||
| Path Failover (MPIO) |
MPIO Basic Failover for Windows provides a single multi-path solution for HP StorageWorks MSA2000sa G2 Modular Smart Array on HP ProLiant servers by providing basic path failover. Supports Windows 2008, Windows 2003, Windows 2003 R2, and Windows 2003 X64 operating systems.
|
||
| HP StorageWorks Storage Mirroring |
HP StorageWorks Storage Mirroring Software provides host-based, continuous
replication for customers seeking a low-cost alternative to fabric or
array-based replication. Patented replication and failover technology
continuously captures byte-level data changes as they happen and replicates
those changes to one or more target servers at any location without geographic
limitations. By replicating only the bytes that change, Storage Mirroring
Software uses the absolute minimum bandwidth on your existing LAN or WAN
to replicate your data. Storage Mirroring also provides server failover
where a production server can automatically be 'replaced' by the storage
mirroring server in the event of failure. Couple Storage Mirroring with
MSA2000 Snapshots and/or Volume Copy to achieve an Enterprise class data
protection strategy creating different data recovery points using continuous
data protection with Storage Mirroring and point-in-time data protection
with Snapshots and/or Volume Copy.
For more information visit: http://h18006.www1.hp.com/products/storage/software/sm/index.html |
||
| HP Storage Mirroring Software Server Edition Stock LTU |
TA711A
|
||
| HP Storage Mirroring SW Enterprise Server Edition Stock LTU |
TA712A
|
||
| HP Storage Mirroring Software NAS Edition Stock LTU |
TA713A
|
||
| HP Storage Mirroring Software 5 Virtual Machines Stock LTU |
TA714A
|
||
| HP Storage Mirroring Software Linux Edition Stock LTU |
TA717A
|
||
| HP Storage Mirroring SW Virtual Infrastructure Ed Stock LTU | TA718A | ||
| HP Storage Mirroring Software Server Image Copy Stock LTU | TA719A | ||
| HP Storage Mirroring Software Data Migration Stock LTU | TA722A | ||
| HP Storage Mirroring for Hyper-V Standard Edition Stock LTU | TA737A | ||
| HP Storage Mirroring for Hyper-V Enterprise Edition Stock LTU | TA735A | ||
| HP Storage Mirroring for Hyper-V Data Center Edition Stock LTU | TA733A | ||
|
|
Service and Support, HP Care Pack, and Warranty Information
| Warranty |
Enclosures, Hard drives, and Options for the MSA2000sa
G2 carry their own warranty. Refer to HP's Limited Warranty Statement
for more information.
The MSA2000sa has been designed with customer self repairable parts to minimize repair time and provide greater flexibility in performing defective parts replacement. Please refer to HP's limited warranty Statement and parts replacement instructions for further details. http://h18006.www1.hp.com/products/storageworks/warranty.html Products included in various Kits carry their own individual warranties. NOTE: The warranty of the hard drive options purchased with the MSA2000sa product is different for SAS hard drives versus SATA hard drives. SAS hard drive options have a three year warranty and SATA hard drives options have a one year warranty. Reference HP's communication for further details: http://www.hp.com go to search, enter CN0089W |
|
|
|
| HP Care
Pack Services. Scalable, Flexible, Dependable. Like your storage. Your storage is evolving. Get scalable support that evolves with it. HP Care Pack Services is an easy-to-buy, easy-to-use portfolio of packaged services covering your lifecycle needs. You can rely on our highly skilled, HP certified professionals to offer a breadth of expertise across leading storage technologies, and work side by side with you for optimal results. Partner with HP Technology Services to boost availability and avoid costly downtime by mitigating technology-related business risks. To help take the worry out of deploying, supporting and managing your storage technologies, we've designed a portfolio of service options that are as flexible, scalable and affordable as our storage. Protect your business beyond the warranty Standard warranty protects against product defects and some causes of downtime. HP Care Pack Services helps you proactively guard against unplanned downtime which can reduce your productivity and profitability. By using a standard approach to warranty uplifts, such as HP Care Pack Services, customers can be certain of consistency of operations for both mission-critical and standard business computing. Extending warranties with HP Care Pack Services The key to normalizing the warranty of combined solutions-is making service uplift simple: HP Care Pack Services. This portfolio of predefined packages, extending across the entire IT lifecycle, offering consulting, education, technical support, optimization, risk assessment, and more. It's entirely flexible allowing customers to extend the cover to the precise level of support required. Customer's standard hardware warranty, for example, can be upgraded to next-business-day response, to same-day coverage, or even to a committed six-hour call-to-repair service available 24 hours every day of the week. Provide consistent, predictable levels of support across your entire department or business Give you direct access to proven technical and problem-solving expertise Offer a choice of response-time and repair-time commitments Are available whenever and wherever you do business For many products, post-warranty HP Care Pack Services are available when your original warranty has expired. Choose the support levels that meet your business requirements, from basic to mission-critical. In the new world of business technology, when your technology has to work for your business to work, who can you trust to make your technology work? HP Technology Services, the trusted business technology experts who manage your technology in action, because when technology works, business works. http://www.hp.com/hps/storage NOTE: Care Pack Services availability may vary by product and country. |
||||
| Product Number | Product Name | Service Name | Care Pack Services Product # and Band |
Alternate Care Pack Services Product # |
| HP StorageWorks MSA Family Disk Array Installation and Startup Service | Contact your HP sales rep or Channel Partner for assistance | UA868A/E | ||
| AJ948A | HP StorageWorks 2012 Modular Smart Array 3.5-in Drive Bay Chassis (LFF) | 3-Year HP Support Plus 24 | ||
| AJ949A | HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay Chassis (SFF) | 3-Year HP Support Plus 24 | ||
| AJ808A | HP StorageWorks 2300sa G2 Modular Smart Array Controller | 3-Year HP Support Plus 24 | ||
| AJ749A | HP StorageWorks MSA2000 Single I/O 3.5-inch 12 LFF Drive Enclosure | 3-Year HP Support Plus 24 | ||
| AJ750A | HP StorageWorks MSA2000 Dual I/O 3.5-inch inch 12 LFF Drive Enclosure | 3-Year HP Support Plus 24 | ||
| AJ751A | HP StorageWorks MSA2000 Drive Enclosure I/O Module | 3-Year HP Support Plus 24 | ||
| 418800-B21 | HP StorageWorks MSA70 2.5-inch 25 SFF Drive Enclosure 2.5 in Drive Enclosure | 3-Year HP Support Plus 24 | ||
| AG779A | HP StorageWorks Dual Domain I/O Module for MSA70 enclosure | 3-Year HP Support Plus 24 | ||
| AJ950A | HP StorageWorks 2012 Modular Smart Array 3.5-in Drive Bay DC-power Chassis (LFF) (can add one or two MSA2300sa G2 controllers or MSA2000 JBOD I/O modules) | 3-Year HP Support Plus 24 | ||
| AJ951A | HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay DC-power Chassis (SFF) (can add one or two MSA2300sa G2 controllers. (No MSA2000 JBOD I/O module support) | |||
| AM337A | HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay Carrier-Grade Chassis (SFF) | |||
| AJ754A | HP StorageWorks 2000sa Modular Smart Array Controller (limited use) | |||
| AP813A | HP StorageWorks 2324sa G2 Modular Smart Array DL380 G6 Package Cluster | |||
| AP716A | HP StorageWorks 2000sa Modular Smart Array 3Gb SAS BL Switch Bundle | |||
|
|
||||
| Services that will enhance the user experience in many product deployments. | |||
| HP Proactive Select Service | HP Proactive
Select Service improves IT performance and manageability through the use
of cost effective flexible proactive services. This proactive service allows
you to accelerate the ROI of your technology environment, by tailoring specific
services to more quickly take advantage of your investment. http://h20195.www2.hp.com/v2/GetPDF.aspx/4AA2-3842ENN.pdf |
||
| HP Entry Storage Data Migration Service for Windows | HP Entry
Storage Data Migration Service for Windows offers you a cost competitive
and convenient way to accommodate data migration triggered by a need to
refresh or consolidate storage, or to create different storage tiers. This
service offers a migration cost in line with the costs of storage products
in small and medium-sized storage environments. The service is delivered
via a skilled HP service specialist with special consideration for data
availability, integrity, and ongoing operational performance during the
transfer process. http://h20195.www2.hp.com/v2/GetPDF.aspx/4AA2-4734ENW.pdf |
||
| Service Name | Care Pack Services
Product # and Band |
Alternate Care Pack Service Product # | |
| HP Proactive Select Service | Contact your HP sales rep or Channel Partner for assistance | Contact your HP sales rep or Channel Partner for assistance | |
| HP Entry Storage Data Migration Service for Windows | Contact your HP sales rep or Channel Partner for assistance | Contact your HP sales rep or Channel Partner for assistance | |
|
|
|||
| eSupport |
HP eSupport is a portfolio of technology-based services
that assist you with managing your business environment - from the desktop
to the data center.
Support Portal The HP support portal provides one-stop access to the information, tools and services you need to manage the daily operations of your IT environment. Features include:
Access to certain features of the support portal requires
an HP service agreement. To access the support portal, visit: http://www.hp.com/support
Remote Support Technology (RST)-HP Remote Support Pack Taking a more proactive approach to IT support, the HP Remote Support pack plug-in module easily integrates with HP Systems Insight Manager to provide a powerful, unified "single pane of glass" solution for onsite and remote management. HP Remote Support Pack enhances HP Systems Insight Manager with intelligent event diagnosis plus the automatic submission of hardware event notifications securely to HP support, including acknowledgment and status returns. It adds remote configuration collections to allow the delivery of assessment and proactive services for your SAN storage and HP-UX environments. |
|
|
|
| Customer Technical Training | Consider education as an integral part of your strategy to get the best return on investment for your HP storage solution. HP offers a variety of training courses on storage software, networking, archiving and disk storage systems. Our classes are available in many delivery modalities from traditional instructor-led courses at one of our 80 training centers worldwide to on-site training customized to your needs or online. www.hp.com/learn/storage |
|
|
|
| HP Services Awards | HP Services continues to be recognized for service and support excellence by customers, partners, industry organizations and publications around the world. Recent honors and award reflect our services team's dedications, technical expertise, professionalism and uncompromising commitment to customer satisfaction. For a list of all our awards, please visit: http://h20219.www2.hp.com/services/cache/433028-0-0-225-121.html |
|
|
|
| Additional Services Information | For more information
about HP Care Pack Services for Storage, please visit: http://www.hp.com/hps/storage If you have specific questions, contact your local HP representative. Contact information for a representative in your area can be found at "Contact HP" http://www.hp.com |
|
|
Configuration Information
![]() |
|||
|
Dual Controller MSA2000sa G2
|
|||
| 1. | Expansion Port | 4. | Service Port |
| 2. | Ethernet Port | 5. | SAS host Ports |
| 3. | CLI Port | 6. | Power Switch |
|
|
|||
![]() |
|||||
|
MSA70 Dual I/O 2.5-inch 25 Drive Enclosure
|
|||||
| Rear Panel components | |||||
| 1. | Power Supply 1 | 4. | SAS in connector | 7. | I/O module bay |
| 2. | System fan 1 | 5. | SAS out connector | 8. | System fan 2 |
| 3. | Dual 7 segment display board | 6. | I/O module bay | 9. | Power supply 2 |
|
|
|||||
![]() |
|||
|
MSA2000 Dual I/O 3.5 inch 12 Drive
Enclosure
|
|||
| 1. | Service Port | 5. | AC Power Good |
| 2. | Unit Locator | 6. | SAS In Port |
| 3. | Power Switch | 7. | SAS Out Port |
| 4. | DC Voltage / Fan Fault | ||
|
|
|||
| Step 1 - MSA2000sa G2- Base Configuration | ||
| Select one: | ||
| Model Name | Model Description: |
Part Number
|
| HP StorageWorks 2012 Modular Smart Array 3.5-inch Drive Bay Chassis | Controller-less chassis with twelve Large Form Factor (LFF) MSA2 drive bays. Space for two controllers. |
AJ948A
|
| HP StorageWorks 2024 Modular Smart Array 2.5-inch Drive Bay Chassis | Controller-less chassis with twenty-four Small Form Factor (SFF) ProLiant drives bays. Space for two controllers. |
AJ949A
|
| There are two array-head chassis - one with twelve 3.5-inch large form factor bays, the other with twenty-four 2.5-inch small form factor drive bays. For additional twelve additional drive bays purchase an MSA2000 3.5-inch Disk Enclosure. You may attach a total of four MSA2000 Drive Enclosures for a total of sixty LFF drives. For 25 additional SFF drive bays purchase an MSA70 JBOD with the 2nd I/O module. You may attach a total of three MSA70 JBODs for a total of ninety-nine SFF drives. Single controller arrays support Single I/O Disk Enclosures; dual controller arrays support Dual I/O Disk Enclosures. | ||
|
|
||
| Step 2 - Options | ||
| Select each option with quantities specified. | ||
| Step 2a - Options | ||
| Description with Parts Shipped: | Quantity | Part Number |
| HP StorageWorks 2300sa G2 Modular
Smart Array Controller (for either the LFF MSA2012, SFF MSA2024, or the two DC-powered chassis) |
1 or 2 | AJ808A |
| Step 2b - Choose Supported Options For SAS HBA | ||
| Select each required option with quantities specified. | ||
| SAS HBA | Description with Parts Shipped: | Part Number |
| HP SC08Ge HBA | SAS HBA to connect to a host | 488765-B21 |
| Step 2c - MSA2 SAS
and SATA Drive Options NOTE: SATA drives are designed for archival or reference data. They should not be used in a heavy or intense I/O environment. Those situations require the use of enterprise-class SAS drives. MSA2 3.5-inch drives are for use only with MSA2000 products. |
||
| MSA2 Large Form Factor (LFF) SAS drives for MSA2000 3.5-inch Drive Chassis and Enclosure | ||
| HP StorageWorks MSA2 146GB 3G 15K 3.5 inch Dual-port SAS HDD | AJ735A | |
| HP StorageWorks MSA2 300GB 3G 15K 3.5 inch Dual-port SAS HDD | AJ736A | |
| HP StorageWorks MSA2 450GB 3G 15K 3.5 inch Dual-port SAS HDD | AJ737A | |
| MSA2 Large Form Factor (LFF) SATA drives for MSA2000 3.5-inch Drive Chassis and Enclosure | ||
| HP StorageWorks MSA2 500GB 7.2K 3.5 inch SATA HDD | AJ738A | |
| HP StorageWorks MSA2 750GB 7.2K 3.5 inch SATA HDD | AJ739A | |
| HP MSA2 1TB 7.2K rpm 3.5 inch SATA HDD | AJ740A | |
| ProLiant Small Form Factor (SFF) SAS drives for MSA2000 2.5-inch Drive Chassis and MSA70 JBOD | ||
| HP 72GB 3G 10K 2.5-inch SAS SFF DP HDD | 384842-B21 | |
| HP 146GB 3G 10K 2.5-inch SAS SFF DP HDD | 418367-B21 | |
| HP 300GB 3G 10K SAS 2.5-inch SFF DP HDD (not supported for rack-level CTO at this time) | 492620-B21 | |
| HP 36GB 3G 15K 2.5-inch SAS SFF DP HDD | 418369-B21 | |
| HP 72GB 3G 15K 2.5-inch SAS SFF DP HDD | 418371-B21 | |
| HP 146GB 3G 15K 2.5-inch SAS DP HDD | 504062-B21 | |
| HP 72GB 3G 10K 2.5-inch SAS SFF SP HDD (MSA70 only) | 375861-B21 | |
| HP 146GB 3G 10K 2.5-inch SAS SFF SP HDD (MSA70 only) | 431958-B21 | |
| HP 36GB 3G 15K 2.5-inch SAS SFF SP HDD (MSA70 only) | 431933-B21 | |
| HP 72GB 3G 15K 2.5-inch SAS SFF SP HDD (MSA70 only) | 431935-B21 | |
| ProLiant Small Form Factor (SFF) SATA drives for MSA2000 2.5-inch Drive Chassis and MSA70 JBOD | ||
| HP 60 GB 1.5 G 5.4K 2.5-inch SATA SFF HDD | 379306-B21 | |
| HP 250 GB 3G 5.4K 2.5-inch SATA ETY HDD | 460355-B21 | |
| HP 120 GB 1.5G 5.4K 2.5-inch SATA SFF HDD | 458924-B21 | |
| Step 2d - Drive Enclosure Options | ||
| Should you want a drive enclosure, the model you choose depends on which array model it attaches to. If it is a single controller array, then choose the JBOD designated as "Single I/O". If it is attaching to a dual controller array then choose the "Dual I/O" JBOD | ||
| HP StorageWorks MSA2000
Single I/O 3.5-inch 12 Drive Enclosure (use with single controller array heads. Ships with two .6m SAS to SAS cables) |
AJ749A | |
| HP StorageWorks MSA2000
Drive Enclosure I/O Module (Use to upgrade the Single I/O model to dual I/O. No cable included) |
AJ751A | |
| HP StorageWorks MSA2000
Dual I/O 3.5-inch 12 Drive Enclosure (use with dual controller array heads. Ships with two .6m SAS to SAS cables) |
AJ750A | |
| HP StorageWorks 70
Modular Smart Array (MSA70) SFF 2.5-inch drive Single I/O JBOD Single I/O, single domain. 25 Small Form Factor (SFF) drive bays (use only with MSA2324sa G2 array head. Includes one miniSAS to miniSAS cable) |
418800-B21 | |
| HP StorageWorks Dual
Domain I/O Module for MSA70 Makes the standard MSA70 (above) into a dual I/O, dual domain JBOD (Includes one miniSAS to miniSAS cable) |
AG779A | |
| MSA70
NOTE: Only Dual Port (DP) drives will work in the Dual Domain environment.
Dual Domain environment requires the HP StorageWorks Dual Domain I/O Module
Option (# AG779A). For more information on the MSA70, go to the MSA70 Home Page: http://h18006.www1.hp.com/storage/disk_storage/msa_diskarrays/drive_enclosures/msa70/index.html |
||
| Step 2e - SAS Cable Options | ||
| Connecting MSA2300sa G2 Controller to an HBA | ||
| Model Description | Part Number | |
| mini-SAS 4x 1M Cable All | 407337-B21 | |
| mini-SAS 4x 2M Cable All | 407339-B21 | |
| mini-SAS 4x 4M Cable All | 432238-B21 | |
| miniSAS to miniSAS
Cables: Connecting MSA2300sa G2 controller to MSA70 JBOD if a longer cable is desired. |
||
| HP Ext miniSAS to miniSAS 1m Cable | 407337-B21 | |
| HP Ext miniSAS to miniSAS 2m Cable | 407339-B21 | |
| SAS to miniSAS
Cables: Connecting MSA2300sa G2 controller to MSA2000 3.5-inch Disk Enclosure |
||
| HP SAS to miniSAS .5m Cable | 419569-B21 | |
| HP SAS to miniSAS 1m Cable | 419570-B21 | |
| HP SAS to miniSAS 2m Cable | 419571-B21 | |
| SAS Cables (SAS
to SAS) Older MSA2000sa controller to MSA2000 3.5-inch Disk Enclosure or cascading two MSA2000 3.5-inch Disk Enclosures if included .6m cables is not of sufficient length |
||
| HP Ext SAS to SAS 1m Cable | 389665-B21 | |
| HP Ext SAS to SAS 2m Cable | 389668-B21 | |
|
|
||
| Step 3 - Other MSA2000sa Options | ||
| Description | Quantity | Part Number |
| HP StorageWorks 2000sa Modular Smart
Array Controller (ONLY for those desiring to configure an older MSA2012sa by using the MSA2012 chassis and installing either one or two of this model controller. The resulting array head will have the attributes of the first generation MSA2012i with no support for SFF drives, limited total drive count, limited snaps, etc.) |
AJ754A | |
| Must choose optional Power Cord
for Non-U.S. Configurations NOTE: Shipped standard with all units. 2 ea. Power Cord, 110/220 VAC, US/Canada/Mexico 227099-001 |
||
| Power Cord, 220/240 VAC, (US/Canada/Mexico) | 2 | 227099-001 |
| Power Cord, (Australia/China/New Zealand) | 2 | 227098-001 |
| Power Cord, (Central Europe) | 2 | 157215-001 |
| Power Cord, (United Kingdom/Hong Kong) | 2 | 157216-001 |
| Power Cord, (Switzerland) | 2 | 157219-001 |
| Power Cord, (Italy) | 2 | 157217-001 |
| Power Cord, (Denmark) | 2 | 157218-001 |
| Power Cord, (Japan) | 2 | 139867-001 |
| Power Cord, (South East Asia/India) | 2 | 157220-001 |
|
|
||
|
Step 4 - Choose Rack Options | |
|
Select each required option with quantities specified.
| |
|
Rack Cabinet, Customer Assembled
| |
| 5642 - 5000 Series rack | 358254-B21 |
| 14U rack | |
| HP S10614 Rack with Shock Pallet | 292302-B22 |
| Rack Cabinets 10622 G2 | |
| 10622 G2 Universal Rack w/Shock Pallet | AF022A |
| 10622 G2 Universal Rack w/Standard Pallet | AF021A |
| Rack Cabinets under 10636 G2 | |
| 10636 G2 (36U) Rack Cabinet - Pallet | AF011A |
| 10636 G2 (36U) Rack Cabinet - Shock Pallet | AF012A |
| 10636 G2 (36U) Rack Cabinet - Crated | AF013A |
| 10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet | AF014A |
| Rack Cabinets 10642 G2 | |
| 10642 G2 (42U) Rack Cabinet - Pallet | AF001A |
| 10642 G2 (42U) Rack Cabinet - Shock Pallet | AF002A |
| 10642 G2 (42U) Rack Cabinet - Crated | AF003A |
| 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet | AF004A |
| Modular Cooling System G2 (MCS G2) | AF025A |
| MCS G2 10642 G2 Expansion Rack | AF026A |
| Rack Cabinets 10842 G2 | |
| 10842 G2 Universal Rack w/Shock Pallet | AF042A |
| 10842 G2 Universal Rack w/Standard Pallet | AF041A |
| Rack Cabinets 10647 G2 | |
| 10647 Rack G2 Pallet | AF031A |
| | |
|
Configure to Order (CTO) Program Information |
||
|
HP introduces the new Configure to Order program for the
MSA2000 family The MSA2000 models and options may or may not be factory
installed in a rack with add-on controllers, switches, hubs, MSA2000 disk
enclosures and hard drives. The MSA2000 arrays may be integrated with
ProLiant servers or as standalone storage.
Orders to be shipped through the CTO process must have a minimum of two drives ordered per controller. |
||
| Description | Product # | |
| HP StorageWorks 2012 Modular Smart Array 3.5-in Drive Bay Chassis (LFF) | AJ948A#0D1 | |
| HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay Chassis (SFF) | AJ949A#0D1 | |
| HP StorageWorks 2300sa Modular Smart Array Controller | AJ808A#0D1 | |
| HP StorageWorks 2312sa G2 Dual Controller Modular Smart Array (LFF) | AJ805A#0D1 | |
| HP StorageWorks 2324sa G2 Dual Controller Modular Smart Array (SFF) | AJ807A#0D1 | |
| HP 2000sa Modular Smart Array Controller (ONLY for use by those wishing to build an older model MSA2012sa) | AJ754A#0D1 | |
| HP MSA2000 3.5-inch Single I/O 12 Drive Encl | AJ749A#0D1 | |
| HP MSA2000 3.5-inch Dual I/O 12 Drive Encl | AJ750A#0D1 | |
| HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay Carrier-Grade Chassis | AM337A#0D1 | |
| HP StorageWorks 2012 Modular Smart Array 3.5-in Drive Bay DC-power Chassis (LFF) | AJ950#A0D1 | |
| HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay DC-power Chassis (SFF) | AJ951A#0D1 | |
| HP MSA2000 Drive Enclosure I/O Module (for CTO, only available for use in a AJ950A DC-powered chassis) | AJ751A#0D1 | |
| HP MSA2 146GB 3G 15K 3.5-inch SAS HDD | AJ735A#0D1 | |
| HP MSA2 300GB 15K 3.5-inch SAS HDD | AJ736A#0D1 | |
| HP MSA2 450GB 3G 15K 3.5-inch SAS HDD | AJ737A#0D1 | |
| HP MSA2 500GB 7.2K 3.5-inch SATA HDD | AJ738A#0D1 | |
| HP MSA2 750GB 7.2K 3.5-inch SATA HDD | AJ739A#0D1 | |
| HP MSA2 1TB 7.2K 3.5-inch SATA HDD | AJ740A#0D1 | |
| MSA70 | Single I/O, single domain 25 Small Form Factor (SFF) drive bays |
418800-B21 |
| MSA70 I/O Module | HP StorageWorks Dual Domain I/O Module | AG779A |
| Makes the standard
MSA70 (above) into a dual I/O, dual domain JBOD NOTE: The I/O Module is a field upgradeable Option Kit the addition of which in the MSA70 will allow dual domain capability providing higher level of redundancy and reliability |
||
| SAS Drives (SFF 2.5-inch) | HP 72GB 3G 10K SAS 2.5-inch SFF DP HDD | 384842-B21 |
| HP 146GB 3G 10K SAS 2.5-inch SFF DP HDD | 418367-B21 | |
| HP 300GB 3G 10K SAS 2.5-inch SFF DP HDD | 492620-B21 | |
| HP 146GB 3G 15K 2.5-inch SAS DP HDD | 504062-B21 | |
| HP 36GB 3G 15K SAS 2.5-inch SFF DP HDD | 418369-B21 | |
| HP 72GB 3G 15K SAS 2.5-inch SFF DP HDD | 418371-B21 | |
| NOTE: Only Dual Port (DP) drives will work as dual-port in a Dual Domain environment. Dual Domain environment requires the HP StorageWorks Dual Domain I/O Module Option (# AG779A). | ||
| SATA Drives (SFF 2.5-inch) | HP 60 GB 1.5 G SATA 5.4K 2.5-inch SFF HDD | 379306-B21 |
| HP 120 GB 1.5G SATA 5.4K 2.5-inch SFF HDD | 458924-B21 | |
| HP 250 GB 3G 5.4K 2.5-inch SATA ETY HDD | 460355-B21 | |
| NOTE: SATA drives
for the MSA70 are not dual port (DP) drives. NOTE: Go to the HP Hard Drive Compatibility table for complete drive compatibility information (http://www.hp.com/products/harddiskdrives). Using hard drives in unsupported configurations will result in voiding the warranty and could result in damage to the drive and/or loss of data |
||
|
|
Technical Specifications
| MSA2000 Chassis | POWER REQUIREMENTS | |
| Input Power Requirements | 110 VAC 3.6A/394W; 220VAC 1.9/385W | |
| Max Input Power | 100-240 VAC, 50/60 Hz., 4.5-1.9A; 48-60 VDC 10.4A/8.3A | |
| Heat Dissipation | 1622 BTU/hr | |
| TEMPERATURE AND HUMIDITY RANGES | ||
| Operating Temperature | 41°F to 104°F (5oC to 40°C) | |
| Shipping Temperature | -40°F to 158°F (-40°C to 70°C) | |
| Operating Humidity | 10% to 90% RH @ 104°F (40°C) non-condensing | |
| Non-Operating Humidity | Up to 93% RH @ 104°F (40°C) | |
| DECLARED ACOUSTIC NOISE LEVELS | ||
| Sound Power | < 6.5 Bels | |
| Sound Pressure | < 57 dBA | |
| SHOCK AND VIBRATION | ||
| Shock, Operational | 5G's for 11 milliseconds, half sine | |
| Shock, Non-Operational | 15G 11ms half sine | |
| Vibration, Operational | 5-500Hz, 0.21Grms flat spectrum0.000089g2/HZ Random Vibration | |
| Vibration, Non-Operational | 5-500-5Hz, 0.5 G peak to peak, sinusoidal | |
| PHYSICAL | ||
| Height | 3.436 in/ 8.727 cm | |
| Depth (excluding cables) (back of ear to back of controller handle) | MSA2024: 20.28 in / 51.510 cm
MSA2012: 21.8 in. / 55.372 cm |
|
| Width (body only) | 17.55 in / 44.58 cm (w/ ears 19 in / 48.26 cm) | |
| Chassis Weight (no controllers) |
MSA2012 chassis: 44 lbs. MSA2024 chassis: 43 lbs | |
|
MSA2000sa G2 Controller |
Host Interface | 4 x4 lane SAS ports - 3Gb/s per lane |
| Protocol Support | SAS | |
| RAID Support | 0, 1, 3, 5, 6, 10, 50 | |
| Cache Memory | 1GB Read/Write | |
| Cache Backup | ECC protection with back up to flash memory ( indefinite backup) | |
| Upgradeable Firmware | yes | |
| Disk Drive and Enclosure Protocol Support | 3Gb SAS - Serial Attached SCSI / 3 Gb SATA II | |
| Expansion Port | One 4X SAS connector (SFF8470) Expand up to 3 more drive enclosures |
| Regulatory |
Safety |
UL 60950-1:2003 (USA)
|
|
CAN/CSA-C22.2 No.60950-1-03 (Canada)
|
||
|
EN 60950-1 :2001 + A11 (European Union)
|
||
|
IEC 60950-1 :2001 (International)
|
||
|
Electromagnetic Compatibility
|
CFR 47 Part 15 Subpart B (U.S.A., Class A)
|
|
|
ICES-003 Issue 4 (Canada, Class A)
|
||
|
EN 55022 :98 +A1 +A2 (European Union, Class A)
|
||
|
EN61000-3-2:2000+A1,+A2,+A14 (Harmonics)
|
||
|
EN 61000-3-3 :2001 (Flicker)
|
||
| EN 55024 :1998 +A1 (European Union, Immunity) | ||
|
CISPR 22 :2005 (International, Class A)
|
||
|
CISPR 24 :97 (International, Immunity)
|
||
| RoHS and WEEE |
RoHS-5 Compliance , China RoHS, WEEE
|
|
| Country Approvals |
Australia/New Zealand, Canada, China (PRC), European Union,
Germany (GS Mark), Japan, South Korea, Taiwan, United States
|
|
© Copyright 2009 Hewlett-Packard Development Company, L.P. |